Smartchem Discrete Auto Analyzer

Time:02-01,2009  Source:  Author:


Smartchem Discrete Auto Analyzer

Incorporated in 1987 and YDI group subsidiary since 2001, Alliance instruments is specialised in development, production and distribution high precision analyzers for food and environment markets.
Smartchem is one the more attractive Discrete analyzer on the market. Especially design for industrial, environmental and food analysis. Smartchem offer a simple and efficient solution to manage a large type of routine analysis, enzymatic or colorimetric. Smartchem is ideal to measure various acids in wines or nutrients or other ions in all type of water including poluted ones. Equipped with a cadmium coil module, it allow you to measure Nitrate according ISO or EPA approved methods.SmartChem is EPA conference call in 2004 and Federal letter for NPDES 2005.

Principle

Each sample is reacted in a “discrete” cuvette. Robotics are used to automate the process. Mimics the operation of a bench chemist.

Features

  • 9 optical filters, plus 1 dark filter, ranging from 340 to 880nm with others optionally available.
  • One sample more parameter
  • True sample blanking
  • Each reaction in its own cuvette, low cross contamination
  • No flowing streams, no pump tubes, no baseline stabilization, no shutdown, no hardware changes, low reagent & sample consumption, minimize hazardous waste, reduce operating costs
  • High level of automation, ease of use/simple operation, true unattended operation
  • Multiple methods in batch mode, automatic “switch-over”, auto dilution of samples, standards
  • Computer controlled micro pipettor, precise dispensing of all liquids, probe cleaning after every liquid contact, prevents cross contamination and carryover, reduce of reagents and hazardous wastes , an integral sensor for low level alerts
  • Automatic cuvette cleaning provides continuous operation, optical integrity of each cuvette is verified before each use
  • Nitrate - nitrite module: replicates US EPA method # 353.2, automated cadmium reduction of nitrate to nitrite followed by diazotization and coupling
  • Continuous sample loading
  • Photometer: A high resolution, dual beam digital detector , expanded absorbance range to 2.500 AUFS , reduces the need to reanalyze over range samples

Specification

  • Fully automated―random access, continuous loading, benchtop analyzer
  •  Assay type: end point, kinetic, differential, bichromatic and immunoturbidimetric assays; up to 100 different tests, all user programmable
  • Test entry mode: selective-profiles-batch-urhent
  • On line reagents:2 racks are provided to contain up to 16 reagents-1 rack cooled by peltier cells for 10 reagent positions and 1 rack at room temperature for 6 reagent positions and 10 standards and controls. 2 more positions for dilution
  • Samples loading: 5 racks for continuous loading of samples split in:-126 positions for routine or urgent samples
  • Sample tube size: max 16mm×100mm(height)
  • Urgent sample analysis: allowed at any time
  • Throughput: up to 200 tests/ hour
  • Incubation temperature: 37℃
  • Reading system: direct photometry
  • Mini reaction volume: 300µl
  • Optics system:
      Photometer: multi-wavelength optics, double beam
      Wavelength: 8 narrow band interferential filters
      Source: halogen lamp 6V/10W
      Optical path: 10mm
       Linear range: 0.001~2.500Abs
       Resolution: 0.0001Abs
  •  Sampling system: One mechanic arm provides all sampling operation with:
    Capacity liquid level sensor
    Reagent pre-warming at 37℃
    Automatic probe washing
    Sample volume: 3.0µl ~300µl(1µl incr)
    Reagent volume: 3.0µl ~300µl(1µl incr)
  • Dilutor: Dilutions are made without using traditional syringes(up to 100 times)
  • Reaction plate: circular 60 semi-disposable cuvettes tray with following characteristics
  • Installation
    Power supply: 90~250VAC,47/63Hz,300W
    Analytical module: -height:42 cm; -width:65cm; -length:100cm; -weight:65kg
    Water consumption: 2ml/test
    Ambient temperature: 18℃~30℃
    Releative humidity: 20%~85%

Application & Measurement parameters

  • Wastewater: Alkalinity, Ammonia, Chloride, Chlorine, Cyanide, Fluoride, Hardness, Nitrate (Cad Reduction), Nitrate (Hydrazine), Nitrite, Ortho-phosphate, Phenol, Silicate, Sulfate, TKN, TKP, TP (Persulfate Digestion)
  • Soils & Plants: Ammonia, CEC, Nitrate (Cad Reduction), Nitrate (Hydrazine), Phosphates, Boron, Sulfates, Wine Applications, Acetic acid, Ascorbic acid, Citric acid, Gluconic acid, Malic acid, Lactic acid, Glucose + fructose, Glucose + Fructose + Saccharose, Ethanol, Ammonia, Glycerol, Acetaldehyde, Free SO2, Total SO2, Tartaric Acid, NOPA test (available N), Iron, Copper, Calcium, Folin index, OD
  • Food: Acetic acid, Ascorbic acid, Citric acid, Gluconic acid, Malic acid, Lactic acid, Glucose + fructose, Glucose + Fructose + Saccharose, Ethanol , Ammonia, Glycerol, Acetaldehyde, Ammonia, Phosphates, Chlorides, Nitrates (Cadmium reduction), Nitrates (Hydrazine reduction), Nitrites

Manufacturer :Alliance, France

Tip
Return to Home
Home
Comment A total of comments
Username: Password:
Verification Code: Anonymous publication
Recommandations
SMARTCHEM 450
SMARTCHEM 450
Smartchem 170
Smartchem 170
FUTURA
FUTURA
SMARTCHEM 600
SMARTCHEM 600
Relations
Update
Hots
ASDASD 帕納科LOS GATOS RESEARCHAMSYSIRESONONCampbellAirPhoton中國農(nóng)業(yè)科學(xué)院
国产一级 片内射在线视频播放-亚洲中文字幕无码va-国产美女裸身网站免费观看视频-天堂tv亚洲tv日本tv